Описание

  • Read head with guard locking without guard lock monitoring
  • Locking force 650 N
  • With remanence
  • Up to category 4 according to EN ISO 13849-1
  • Two safety screws M5x16 included
Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off. Dimension drawing Circuit diagram connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Material
Read head Plastic (PPS)
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Weight
Net 0,3 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Switching frequency
Read head See operating instructions for the related evaluation unit
Solenoid max.1 Hz
Connection
X3, read head Plug connector M8x1, 3-pin male (with snap-action / screw terminal)
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
Cable length max.25 m
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 650 N
Adhesive force
due to remanence 10 N -25% ... +25%
Electrical connection ratings
Operating voltage DC
UCM 24 V DC -15% ... 10%
Current consumption
UB 100 mA
Power consumption 2,5 W
Solenoid duty cycle 100 %
Work area
Switching hysteresis 0,7 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao min.2 mm
Center offset -2,5 ... +2,5 mm
''